Description
The shield is designed for planar current sensing in combination with a magnetic field sensor, i.e., Hall sensor, AMR sensor and a busbar conductor. The R-Shield protects the sensor from parasitic magnetic fields caused by nearby conductors or other magnetic field sources while at the same time it enhances sensitivity and signal-to-offset ratio of the sensor.
Magnetic Characteristics
Parameter | Typical Value | Unit |
Relative Permeability | 100.000 | a.u. |
Initial Relative Permeability | 7000 | a.u. |
Saturation Flux Density | 1 | T |
Hysteresis | 2.8 | A/m |
Curie Temperature | 450 | degC |
Geometry
(all dimensions: mm)
Material Specifications | R-Shield-…-[T] | -[Ni]-¹ (%) |
Standard thickness: 0.8mm / 48% Ni | T=0.8 | Ni=48 |
Other thickness options 0.35/0.5/1/1.2 mm | T=… | Ni=… |
¹ Standard version contains 48% Ni; others on request