magnetic system design and current measurement solutions

Products

The RC-­chamber is a soft ferromagnetic chamber featuring superior material characteristics such as high linearity, very low hysteresis, and high magnetic permeability.
The DR-10S-A is a dual range current Sensor for safety critical application, offering two independent analog outputs. Thanks to the non-intrusive clamp-on design, the sensor can be easily installed without requiring any disconnection, which makes it ideal for retrofit installations in industrial, IoT and metering applications. Furthermore, a broad dynamic range of currents can be measured and no calibration is required by the customer.
The DI-10S-A is a differential current Sensor for safety critical application, offering two independent analog outputs for full redundancy. Thanks to the non-intrusive clamp-on design, the sensor can be easily installed without requiring any disconnection, which makes it ideal for retrofit installations in industrial, IoT and metering applications. Furthermore, a broad dynamic range of currents can be measured and no calibration is required by the customer.
The CO-10-SF-A is an analog open loop current sensor module designed for non-intrusive and isolated mea- surement of electric currents. Thanks to the clamp-on design, the contactless current sensor can be safely installed without the need to interrupt or cut the cable.
The R25-BAR-03 shunt resistor is a precision Cu-Mn resistance. It consists of a copper busbar with hole terminals for easy installation.
The R35-BAR-03 shunt resistor is a precision Cu-Mn resistance. It consists of a copper busbar with hole terminals for easy installation.
The R50-BAR-03 shunt resistor is a precision Cu-Mn resistance. It consists of a Tin plated copper busbar with hole terminals for easy installation.
The R50-BAR-04 shunt resistor is a precision Cu-Mn resistance. It consists of a Tin plated copper busbar with hole terminals for easy installation.
The R75-BAR-03 shunt resistor is a precision Cu-Mn resistance. It consists of a Tin plated copper busbar with hole terminals for easy installation.
The R100-BAR-03 shunt resistor is a precision Cu-Mn resistance. It consists of a copper busbar with hole terminals for easy installation.
The laminated U-shield is a soft ferromagnetic shield featuring superior material characteristics such as high linearity and very low hysteresis. It is available with two different materials: Ni-Fe and Si-Fe.
The SCT-T24 is a split core current transformer (CT) that enables low-cost and high accuracy current sensing up to 300 Amps.
The U-Shield is a soft ferromagnetic shield featuring superior material characteristics such as high linearity and very low hysteresis.
The P-­chamber is a soft ferromagnetic shield featuring superior material characteristics such as high linearity, very low hysteresis, and high magnetic permeability.
The AMC1R5-L is an amorphous Fe-based soft ferromagnetic core designed for contactless current sensing applications. It is used in combination with a magnetic field sensor, i.e., Hall sensor which is placed in the airgap.
The C-Core is a soft ferromagnetic core featuring superior material characteristics such as high linearity and very low hysteresis.
The HSM-800 is a redundant dual current sensor module combining precise Cu-Mn shunt- based current measurement and a fully redundant, galvanically isolated Hall sensor.
The CO-04-SF-A is an analog open loop current sensor module designed for non-intrusive and isolated mea- surement of electric currents. Thanks to the clamp-on design, the contactless current sensor can be safely installed without the need to interrupt or cut the cable.
The CO-10-SF magnetic field concentrator, is designed for non-intrusive and isolated measurement of electric currents. Thanks to the Clamp-On design, the contact- less current sensor can be safely installed without the need to interrupt or cut the cable.
The CO-04-SF magnetic field concentrator, is designed for non-intrusive and isolated measurement of electric currents. Thanks to the Clamp-On design, the contact- less current sensor can be safely installed without the need to interrupt or cut the cable.
Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Aenean commodo ligula eget dolor. Aenean massa. Cum sociis natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Donec quam felis, ultricies n